Dew Point Calculator

At the entered 75°F air temperature and 55% relative humidity, the model gives a dew point near 58°F, about 17°F below the air temperature. A surface cooling below that dew point can collect condensation. This is a temperature threshold from the entered conditions, not a forecast of when fog will form or a universal comfort rating.

Dew Point Calculator: inputs

Calculated result
Dew point (°F)57.7
Temperature-dew point spread17.3

Dew Point Calculator: Air temperature (°F) sensitivity

Dew Point Calculator: Air temperature (°F) and Dew point (°F)5 calculations vary the “Air temperature (°F)” input while holding the other entered inputs constant.6043.86851.27557.78365.19071.6

The displayed Magnus approximation uses coefficients 17.27 and 237.7 with Celsius temperature internally, then converts back to °F. It requires humidity above 0% and at most 100%. Pressure, the saturation convention and sensor uncertainty matter for precise work; at subfreezing conditions dew point over water and frost point over ice differ.

An unchanged dew point with changing temperature presumes the relevant moisture and pressure conditions remain fixed.

Dew Point: formula

Magnus formula on temperature (°F) and relative humidity (%)

National Weather Service: Heat Index and Wind Chill

Dew Point: worked example

Air temperature (°F)75
Relative humidity55.0%
Dew point (°F)57.7
Temperature-dew point spread17.3

Enter the air temperature in degrees Fahrenheit and the relative humidity as a percent. The Magnus formula estimates the dew point, the temperature at which the air would be saturated and dew begin to form. Take the values from a thermometer and a hygrometer, or a weather report.

The spread between temperature and dew point is also reported, which shows how close the air is to saturation.

Dew Point: changing Air temperature (°F)

Air temperature (°F)Dew point (°F)Temperature-dew point spread
6043.816.2
6851.216.8
75 (example)57.717.3
8365.117.9
9071.618.4

Dew Point: compare input ranges

InputTested fromToDew point (°F): low inputDew point (°F): high inputSwing
Air temperature (°F)688351.265.113.9 (24%)
Relative humidity53.0%57.0%56.758.72 (3.5%)

Dew Point: individual input comparisons

InputValueDew point (°F)Temperature-dew point spread
Air temperature (°F)6043.816.2
6851.216.8
7557.717.3
8365.117.9
9071.618.4
Relative humidity51.0%55.619.4
53.0%56.718.3
55.0%57.717.3
57.0%58.716.3
59.0%59.715.3

Dew Point: combined input changes

Air temperature (°F) / Relative humidity51.0%55.0%59.0%
6041.843.845.6
6849.251.253.1
7555.657.759.7
836365.167.2
9069.471.673.7

Dew Point: which assumptions move the result?

Dew Point: Dew point (°F) as Air temperature (°F) changesDew point (°F) starts at 43.8. Moving Air temperature (°F) from 60 to 90 changes it to 71.6, with Relative humidity 55.0% kept fixed.6043.86851.27557.78365.19071.6
Chart quantityDisplayed settings
Air temperature (°F)60 → 90
Dew point (°F)43.8 → 71.6
Relative humidity55.0%
Dew Point: Dew point (°F) as Relative humidity changesDew point (°F) starts at 55.6. Moving Relative humidity from 51.0% to 59.0% changes it to 59.7, with Air temperature (°F) 75 kept fixed.51.0%55.653.0%56.755.0%57.757.0%58.759.0%59.7
Chart quantityDisplayed settings
Relative humidity51.0% → 59.0%
Dew point (°F)55.6 → 59.7
Air temperature (°F)75

Dew Point: values and definitions

Quantity and definitionValue used
Air temperature (°F)75
Relative humidity55.0%
Dew point (°F)57.7
Temperature-dew point spread17.3

Dew Point: half and double Air temperature (°F)

Air temperature (°F)Dew point (°F)
37.522.8
7557.7
150126.9

Common error: Judging humidity from the relative humidity percentage alone without checking dew point. A cool morning can show a high relative humidity percentage while feeling comfortable, because relative humidity depends on temperature in a way dew point doesn't.

Keep the input temperature scale explicit

For an assumed 20°C air temperature and 50% relative humidity, the displayed approximation gives a dew point of about 9.3°C. At 100% relative humidity the modeled dew point meets the air temperature. Entering the Fahrenheit number 68 into a Celsius field would represent a different condition, not the same room.

Relative humidity is a ratio at the current air temperature; it is not the amount of water in grams per cubic meter. The fitted formula is an approximation under its stated range, so condensation assessment still needs the temperature of the actual surface.

Weather calculators: Heating & Cooling Degree Days Calculator, Snow-to-Liquid Ratio Calculator, Wind Chill Calculator, Heat Index Calculator.

Temperature alone doesn't describe how humid a day feels, but dew point does directly, since a smaller gap between temperature and dew point means the air is closer to saturated and feels more oppressively humid regardless of what the raw temperature reading says on its own.

Compare the temperature-to-dew-point spread, not the raw temperature or humidity percentage alone, when judging how muggy conditions will feel.

See how it feels on the heat index calculator, cold effects on the wind chill page and heating and cooling demand on the degree days calculator. The temperature converter changes units, and the snow-to-liquid page relates to precipitation. Use a dehumidifier when indoor dew points stay high.

Dew Point Calculator: quantities and terminology

What is the dew point?

The temperature to which air must be cooled for water vapor to condense into dew, reflecting how much moisture the air holds.

Why is dew point better than relative humidity for comfort?

Because relative humidity depends on the temperature, while the dew point reflects the actual amount of moisture in the air.

What dew point feels muggy?

Above about 65 degrees Fahrenheit most people feel muggy, and above 70 it feels oppressive.