Electrical Box Fill Calculator

Box fill prevents overcrowding, which can overheat wires and make devices hard to install. Four 14-gauge conductors, one device, one ground and a clamp need 16 cubic inches, and an 18 cubic inch box is about 89% full, so it passes. If the required volume exceeds the box's volume, use a larger or deeper box.

Extension rings can add volume in some cases.

Electrical Box Fill Calculator: inputs

Calculated result
Required box volume (cu in)16
Percent of entered box volume used88.9%

#14 AWG conductors and required box volume (cu in)

Electrical Box Fill Calculator: #14 AWG conductors and Required box volume (cu in)5 calculations vary the “#14 AWG conductors” input while holding the other entered inputs constant.212314416518620

Enter the number of conductors by gauge, devices such as switches and receptacles, whether grounding conductors and an internal cable clamp are present and the box volume in cubic inches marked in the box. Under the National Electrical Code, each conductor counts by volume, 2 cubic inches for 14 gauge, 2.25 for 12 gauge and 2.5 for 10 gauge, each device counts as two conductors of the largest size, all grounding conductors together count as one and internal clamps count as one. Count conductors that originate in the box.

Conductors that pass through uncut may count differently from those spliced or terminated, and fixtures and fittings add volume. Rules differ for different wire gauges mixed in a box. Box volume is stamped inside the box or given in the catalog.

Work should follow the adopted code and be done by a qualified person.

Required box volume (cu in) from #14 AWG conductors

#14 AWG conductors4
#12 AWG conductors0
Devices (switches/receptacles)1
Grounding conductors presentYes
Internal cable clamp presentYes
Box volume18
Required box volume (cu in)16
Percent of entered box volume used88.9%

Common error: Counting only the conductors. Devices, clamps and grounds all take volume, and leaving them out puts too much in the box.

Electrical Box Fill: formula

Required volume = Σ conductor allowances + devices×2×largest allowance + ground×largest + clamp×largest (NEC 314.16(B))

NFPA 70: National Electrical Code

Electrical Box Fill: changing #14 AWG conductors

Required box volume (cu in): assumed #14 AWG conductors scenarios.
#14 AWG conductorsRequired box volume (cu in)Percent of entered box volume used
21266.7%
31477.8%
4 (example)1688.9%
518100.0%
620111.1%

Electrical Box Fill: compare input ranges

Electrical Box Fill Calculator: Required box volume (cu in) with each input moved on its own, every other input held at the worked-example value.
InputTested fromToRequired box volume (cu in): low inputRequired box volume (cu in): high inputSwing
Devices (switches/receptacles)0212208 (50%)
#14 AWG conductors3514184 (25%)
#12 AWG conductors011619.33.3 (20%)
Grounding conductors presentYesNo16142 (13%)
Internal cable clamp presentYesNo16142 (13%)
Box volume162016160

Electrical Box Fill: individual input comparisons

Electrical Box Fill Calculator: change one input at a time; other values remain at the stated example.
InputValueRequired box volume (cu in)Percent of entered box volume used
#14 AWG conductors21266.7%
31477.8%
41688.9%
518100.0%
620111.1%
#12 AWG conductors01688.9%
01688.9%
01688.9%
119.3106.9%
221.5119.4%
Devices (switches/receptacles)01266.7%
01266.7%
11688.9%
220111.1%
324133.3%
Grounding conductors presentYes1688.9%
No1477.8%
Internal cable clamp presentYes1688.9%
No1477.8%
Box volume1416114.3%
1616100.0%
181688.9%
201680.0%
221672.7%

Required box volume (cu in): #14 AWG conductors against Devices (switches/receptacles)

Electrical Box Fill: Required box volume (cu in) at combined #14 AWG conductors and Devices (switches/receptacles) settings.
#14 AWG conductors / Devices (switches/receptacles)013
281220
3101422
4121624
5141826
6162028

Electrical Box Fill: values and definitions

Worked-example inputs and the results they produce for the Electrical Box Fill Calculator.
Quantity and definitionValue used
#14 AWG conductors — Count of 14 AWG conductors entering the box.4
#12 AWG conductors — Count of 12 AWG conductors entering the box.0
Devices (switches/receptacles) — Number of switches or receptacles mounted in the box; each counts as two conductors.1
Grounding conductors present — Whether any grounding conductors are present (they count together as one conductor).Yes
Internal cable clamp present — Whether the box has an internal cable clamp (it counts as one conductor).Yes
Box volume — Rated cubic-inch volume of the box.18
Required box volume (cu in)16
Percent of entered box volume used88.9%

Devices (switches/receptacles): half and double

Electrical Box Fill scale comparison; assumed inputs.
Devices (switches/receptacles)Required box volume (cu in)
0.514
116
220

A box has a fixed volume, and the code counts how much room each conductor, device and clamp takes. In the example, four 14 gauge conductors at 2 cubic inches each give 8, a device counts as two allowances, or 4, and the ground and the internal clamp add 2 each, for 16 cubic inches required. An 18 cubic inch box is 88.9 percent used.

Crowding wires into a small box overheats them and makes them hard to install safely.

Read the volume marked inside the box and use the allowance for the largest conductor size present. Add for extra devices, fittings and any additional grounds.

See conduit capacity on the conduit fill calculator, wire ratings on the wire ampacity page and voltage loss on the voltage drop calculator. The cubic feet and rectangular prism pages relate to volumes, and the watts to amps calculator sizes circuits.

What if the box is too full?

Use a larger or deeper box, or an extension ring where allowed, since overfilled boxes are hazardous and violate code.