Wall length and height are feet. The nominal 8-by-16-inch module includes the joint and covers 8/9 ft². The mortar output uses QUIKRETE Type S Mason Mix No.
1136’s published yield of up to 13 standard blocks per 80-lb bag. Actual joints, waste and unit geometry can require more; another product needs its own yield.
Walls with many openings, pilasters or different block heights change the count. Mortar consumption varies with the mason and joint thickness. Structural block walls need reinforcement and grout to code.
Footings and frost depth matter for foundations. Weather affects curing and safety.
Blocks needed from wall length
| Wall length | 20 |
|---|---|
| Wall height | 8 |
| Blocks needed | 180 |
| 80-lb Type S Mason Mix bags (13 blocks/bag) | 14 |
Common error: Forgetting that the block is nominal. The real block is slightly smaller than its nominal size, and the joint fills the difference, so the wall area still divides evenly.
Concrete Block (CMU): formula
Concrete Block (CMU): changing Wall length
| Wall length | Blocks needed | 80-lb Type S Mason Mix bags (13 blocks/bag) |
|---|---|---|
| 16 | 144 | 12 |
| 18 | 162 | 13 |
| 20 (example) | 180 | 14 |
| 22 | 198 | 16 |
| 24 | 216 | 17 |
Concrete Block (CMU): compare input ranges
| Input | Tested from | To | Blocks needed: low input | Blocks needed: high input | Swing |
|---|---|---|---|---|---|
| Wall height | 7 | 9 | 158 | 203 | 45 (25%) |
| Wall length | 18 | 22 | 162 | 198 | 36 (20%) |
Concrete Block (CMU): individual input comparisons
| Input | Value | Blocks needed | 80-lb Type S Mason Mix bags (13 blocks/bag) |
|---|---|---|---|
| Wall length | 16 | 144 | 12 |
| 18 | 162 | 13 | |
| 20 | 180 | 14 | |
| 22 | 198 | 16 | |
| 24 | 216 | 17 | |
| Wall height | 6 | 135 | 11 |
| 7 | 158 | 13 | |
| 8 | 180 | 14 | |
| 9 | 203 | 16 | |
| 10 | 225 | 18 |
Blocks needed: Wall length against Wall height
| Wall length / Wall height | 6 | 8 | 10 |
|---|---|---|---|
| 16 | 108 | 144 | 180 |
| 18 | 122 | 162 | 203 |
| 20 | 135 | 180 | 225 |
| 22 | 149 | 198 | 248 |
| 24 | 162 | 216 | 270 |
Concrete Block (CMU): values and definitions
| Quantity and definition | Value used |
|---|---|
| Wall length — Length of the block wall, in feet. | 20 |
| Wall height — Height of the block wall, in feet. | 8 |
| Blocks needed | 180 |
| 80-lb Type S Mason Mix bags (13 blocks/bag) | 14 |
Wall height: half and double
| Wall height | Blocks needed |
|---|---|
| 4 | 90 |
| 8 | 180 |
| 16 | 360 |
Measure gross face area, subtract actual openings and distinguish modular count from special-unit scheduling. Mortar bags use the selected product’s published laying yield, while reinforcement and filled-cell grout require separate specifications.
Subtract door and window openings and add a small allowance for cuts. Confirm the mortar type your job requires, since bag yields differ.
See mortar on the mortar mix calculator, the footing on the footing size page, reinforcement on the rebar calculator and slab concrete on the concrete volume calculator. The paver and cubic yard pages cover other masonry, and the rectangle area calculator gives the wall area.
Does fourteen bags include construction waste?
No. It rounds 180/13 upward using the specified product’s up-to yield. Mortar lost during mixing or laying, different joints and another mix can change the purchase count.
Is a nominal block sixteen inches long without a joint?
No. Nominal modular dimensions include the joint. Match actual unit dimensions and the planned joint before estimating a nonstandard wall.
How many concrete blocks are in a square foot of wall?
About 1.125 standard 8 by 16 inch blocks per square foot, or roughly 1 block per 0.89 square feet.
How much mortar do I need for 100 blocks?
Use the selected mortar product’s coverage statement together with block size, joint thickness and the manufacturer’s installation assumptions. A bag count from another product or wall detail is not interchangeable. The linked product documentation and a project takeoff are more specific than a universal bags-per-hundred rule.
Should I order extra blocks?
Allow for cuts, breakage, corners, openings and the specified special units in the actual wall layout. The waste percentage is an order-planning assumption rather than a code-prescribed allowance. Check whole-unit counts and the supplier’s packaging before placing an order.