Water Heater Sizing Calculator

Two simultaneous fixtures at 2.5 hot-water GPM require 5 GPM. Ten minutes consumes 50 gallons; adding 10 other gallons in the same peak hour gives 60 gallons to compare with a storage unit’s tested first-hour rating. At a 70°F rise, the approximate delivered heating requirement is 500×5×70 = 175,000 Btu/h.

Compare an actual tankless unit’s flow curve at that rise, not an unrelated maximum-flow label.

Water Heater Sizing Calculator: inputs

Calculated result
Modeled peak-hour hot-water demand (gallons)60
Simultaneous hot-water flow (GPM)5
Approximate delivered heating power (Btu/h)175,000

Duration of simultaneous peak draw (minutes) and modeled peak-hour hot-water demand (gallons)

Water Heater Sizing Calculator: Duration of simultaneous peak draw (minutes) and Modeled peak-hour hot-water demand (gallons)5 calculations vary the “Duration of simultaneous peak draw (minutes)” input while holding the other entered inputs constant.850955106011651270

Enter simultaneous hot-water fixtures and average hot-water flow per fixture, not mixed-flow volume unless all that flow must be heated. Peak minutes is the duration of that draw; other demand adds all additional hot-water gallons in the same busiest hour. Enter required temperature rise from incoming water to delivered hot-water temperature.

All example values are scenarios, not household-size recommendations.

First-hour rating includes storage and recovery and is not identical to nominal tank gallons. The 500 coefficient is an approximate water-density/specific-heat conversion; delivered thermal power is not fuel input, which also depends on efficiency. Mixing, recovery timing, recirculation and actual draw patterns affect service.

This calculation does not approve installation, venting, electrical supply or a particular heater model.

Modeled peak-hour hot-water demand (gallons) from duration of simultaneous peak draw (minutes)

Duration of simultaneous peak draw (minutes)10
Other hot-water gallons during the same peak hour10
Required temperature rise (°F)70
Fixtures used at once2
Average flow per fixture2.5
Modeled peak-hour hot-water demand (gallons)60
Simultaneous hot-water flow (GPM)5
Approximate delivered heating power (Btu/h)175,000

Common error: Choosing a heater by household size alone. Two people who shower back to back can need more than four who stagger their use.

Water Heater Sizing: formula

Peak-hour demand = simultaneous flow × draw minutes + other same-hour gallons; approximate delivered Btu/h = 500 × GPM × temperature rise

IAPMO: Uniform Plumbing Code · PNNL Building America: First-hour demand

Water Heater Sizing: changing Duration of simultaneous peak draw (minutes)

Modeled peak-hour hot-water demand (gallons): assumed Duration of simultaneous peak draw (minutes) scenarios.
Duration of simultaneous peak draw (minutes)Modeled peak-hour hot-water demand (gallons)Simultaneous hot-water flow (GPM)Approximate delivered heating power (Btu/h)
8505175,000
9555175,000
10 (example)605175,000
11655175,000
12705175,000

Water Heater Sizing: compare input ranges

Water Heater Sizing Calculator: Modeled peak-hour hot-water demand (gallons) with each input moved on its own, every other input held at the worked-example value.
InputTested fromToModeled peak-hour hot-water demand (gallons): low inputModeled peak-hour hot-water demand (gallons): high inputSwing
Fixtures used at once13358550 (83%)
Duration of simultaneous peak draw (minutes)911556510 (17%)
Average flow per fixture2.32.8566610 (17%)
Other hot-water gallons during the same peak hour91159612 (3.3%)
Required temperature rise (°F)637760600

Water Heater Sizing: individual input comparisons

Water Heater Sizing Calculator: change one input at a time; other values remain at the stated example.
InputValueModeled peak-hour hot-water demand (gallons)Simultaneous hot-water flow (GPM)Approximate delivered heating power (Btu/h)
Duration of simultaneous peak draw (minutes)8505175,000
9555175,000
10605175,000
11655175,000
12705175,000
Other hot-water gallons during the same peak hour8585175,000
9595175,000
10605175,000
11615175,000
12625175,000
Required temperature rise (°F)56605140,000
63605157,500
70605175,000
77605192,500
84605210,000
Fixtures used at once01000
1352.587,500
2605175,000
3857.5262,500
411010350,000
Average flow per fixture2504140,000
2.3564.6161,000
2.5605175,000
2.8665.6196,000
3706210,000

Modeled peak-hour hot-water demand (gallons): Duration of simultaneous peak draw (minutes) against Other hot-water gallons during the same peak hour

Water Heater Sizing: Modeled peak-hour hot-water demand (gallons) at combined Duration of simultaneous peak draw (minutes) and Other hot-water gallons during the same peak hour settings.
Duration of simultaneous peak draw (minutes) / Other hot-water gallons during the same peak hour81012
8485052
9535557
10586062
11636567
12687072

Water Heater Sizing: values and definitions

Worked-example inputs and the results they produce for the Water Heater Sizing Calculator.
Quantity and definitionValue used
Duration of simultaneous peak draw (minutes) — Enter the duration of simultaneous peak draw (minutes) used in this estimate.10
Other hot-water gallons during the same peak hour — Enter the other hot-water gallons during the same peak hour used in this estimate.10
Required temperature rise (°F) — Enter the required temperature rise (°f) used in this estimate.70
Fixtures used at once — Number of fixtures expected to run at the same time during peak demand.2
Average flow per fixture — Typical flow rate per fixture, in gallons per minute.2.5
Modeled peak-hour hot-water demand (gallons)60
Simultaneous hot-water flow (GPM)5
Approximate delivered heating power (Btu/h)175,000

Fixtures used at once: half and double

Water Heater Sizing scale comparison; assumed inputs.
Fixtures used at onceModeled peak-hour hot-water demand (gallons)
135
260
4110

Sizing a water heater is a question of how much hot water you use at once, not how many people live in the house. A household of three is a common fit for a 40 gallon storage tank, and a tankless unit is sized by flow: two fixtures running at 2.5 gallons a minute each need a unit that heats 5 gallons a minute. Tanks give a reservoir and recover slowly, and tankless units give continuous hot water within their flow limit, so the peak demand decides which fits.

Note when you use the most hot water, such as morning showers plus a dishwasher, and size for that peak. The temperature rise in your area also sets the tankless capacity you need.

Check supply flow on the flow rate calculator, pipe losses on the pipe friction page and the volume of hot water lines on the pipe volume calculator. The watts to amps calculator sizes an electric heater's circuit, and the energy and power converters change units.

Can a 5-GPM label be used at every inlet temperature?

No. Available hot-water flow changes with required temperature rise. Check the actual performance curve for the intended conditions.